The DataPower Gateway must use automated mechanisms to alert security personnel to threats identified by authoritative sources (e.g., CTOs) and in accordance with CJCSM 6510.01B.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-65173 | WSDP-NM-000131 | SV-79663r1_rule | CCI-000366 | medium |
| Description | ||||
| By immediately displaying an alarm message, potential security violations can be identified more quickly even when administrators are not logged into the network device. An example of a mechanism to facilitate this would be through the utilization of SNMP traps. | ||||
| STIG | Date | |||
| IBM DataPower Network Device Management Security Technical Implementation Guide | 2017-10-05 | |||
Related Frameworks
4 paths across 3 frameworks
Related Frameworks
NIST 800-531 mapping
CM-6
1.00
- DISA · V1R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.4.1
1.00
- DISA · V1R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.4.2
1.00
- DISA · V1R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000366
1.00
- DISA · V1R2 · disa_xccdf · related
Details
Check Text (C-79663r1_chk)
Go to Administration >> Access >> SNMP Settings. Verify the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Verify the remote server/receiver information. If these values have not been set, this is a finding.
Fix Text (F-71113r1_fix)
Go to Administration >> Access >> SNMP Settings. Configure the IP address, port, and security settings.
Go to the Trap and Notification Targets tab. Enter the remote server/receiver information.