The DataPower Gateway must prohibit password reuse for a minimum of five generations.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-65093WSDP-NM-000054SV-79583r1_ruleCCI-000200medium
Description
Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. To meet password policy requirements, passwords need to be changed at specific policy-based intervals. If the network device allows the user to consecutively reuse their password when that password has exceeded its defined lifetime, the end result is a password that is not changed as per policy requirements.
STIGDate
IBM DataPower Network Device Management Security Technical Implementation Guide2017-10-05

Related Frameworks

6 paths across 3 frameworks
NIST 800-531 mapping
  • DISA · V1R2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1714 mappings
3.5.10
1.00
  • DISA · V1R2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.5.7
1.00
  • DISA · V1R2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.5.8
1.00
  • DISA · V1R2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.5.9
1.00
  • DISA · V1R2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000200
1.00
  • DISA · V1R2 · disa_xccdf · related

Details

Check Text (C-79583r1_chk)

Search Bar “Administration” >> Access >> RBM Settings >> Password Policy. If Control reuse is Off, this is a finding.

Fix Text (F-71033r1_fix)

Search Bar “Administration” >> Access >> RBM Settings >> Password Policy. Set Control reuse to On, set Reuse history to at least 5.