AIX must employ strong authenticators in the establishment of nonlocal maintenance and diagnostic sessions.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-215213 | AIX7-00-001102 | SV-215213r958510_rule | CCI-000877 | high |
| Description | ||||
| If maintenance tools are used by unauthorized personnel, they may accidentally or intentionally damage or compromise the system. The act of managing systems and applications includes the ability to access sensitive application information, such as system configuration details, diagnostic information, user information, and potentially sensitive application data. Some maintenance and test tools are either standalone devices with their own operating systems or are applications bundled with an operating system. Nonlocal maintenance and diagnostic activities are those activities conducted by individuals communicating through a network, either an external network (e.g., the Internet) or an internal network. Local maintenance and diagnostic activities are those activities carried out by individuals physically present at the information system or information system component and not communicating across a network connection. Typically, strong authentication requires authenticators that are resistant to replay attacks and employ multifactor authentication. Strong authenticators include, for example, PKI where certificates are stored on a token protected by a password, passphrase, or biometric. | ||||
| STIG | Date | |||
| IBM AIX 7.x Security Technical Implementation Guide | 2026-02-06 | |||
Related Frameworks
1 mapping across 4 frameworks
Related Frameworks
SCF0 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (3) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
NIST 800-530 mappings
No source states a mapping between these directly.
Also reachable in 2 hops (44) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)3our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
+34 more (top 10 by confidence shown)
NIST 800-1710 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (1) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
3.7.5
1.00
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
CCI1 mapping
CCI-000877
1.00
- DISA STIG Benchmark (XCCDF)V3R2intersects(normalised)
Details
Check Text (C-215213r958510_chk)
From the command prompt, execute the following to check if "telnetd" is enabled.
# lssrc -t telnet | grep active
If the above command returns output, this is a finding.
Fix Text (F-16409r294091_fix)
Disable telnet by executing the following command:
# stopsrc -t telnet