AIX must provide time synchronization applications that can synchronize the system clock to external time sources at least every 24 hours.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-215208AIX7-00-001053SV-215208r1038944_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144
STIGDate
IBM AIX 7.x Security Technical Implementation Guide2026-06-15

Related Frameworks

4 mappings across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI4 mappings

Details

Check Text (C-215208r1038944_chk)

Check if time synchronization application "ntpd" is running using the command: # lssrc -s xntpd Subsystem Group PID Status xntpd tcpip 4784536 active If "ntpd" is showing "inoperative", this is a finding. Check that "ntp" server is configured using command: # grep server /etc/ntp.conf server 10.110.20.10 If the command returns no output, this is a finding. Check the poll interval is less than 24 hours using command: # grep maxpoll /etc/ntp.conf maxpoll=16 If "maxpoll" is set to larger than "16" (2^16 seconds ~= 18hr), this is a finding.

Fix Text (F-16404r294076_fix)

Edit /etc/ntp.conf Configure ntp server by adding the following line: server server_ipaddr Set maxpoll to <value> <=16 by adding the maxpoll <value>. Restart the ntp daemon. # stopsrc -s xntpd # startsrc -s xntpd