The HP FlexFabric Switch must generate audit log events for a locally developed list of auditable events.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-217479HFFS-ND-000131SV-217479r961863_ruleCCI-000366medium
Description
Auditing and logging are key components of any security architecture. Logging the actions of specific events provides a means to investigate an attack; to recognize resource utilization or capacity thresholds; or to identify an improperly configured network device. If auditing is not comprehensive, it will not be useful for intrusion monitoring, security investigations, and forensic analysis.
STIGDate
HP FlexFabric Switch NDM Security Technical Implementation Guide2025-06-12

Related Frameworks

4 paths across 3 frameworks
NIST 800-531 mapping
CM-6
1.00
  • DISA · V1R4 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.4.1
1.00
  • DISA · V1R4 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.4.2
1.00
  • DISA · V1R4 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000366
1.00
  • DISA · V1R4 · disa_xccdf · related

Details

Check Text (C-217479r961863_chk)

Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding.

Fix Text (F-18701r293113_fix)

Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled.