STIGViewer Support

The HP FlexFabric Switch must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-217466HFFS-ND-000101SV-217466r961443_ruleCCI-001890medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
STIGDate
HP FlexFabric Switch NDM Security Technical Implementation Guide2025-06-12

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (26) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(9)Disconnect or Disable Access
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-14(2)Capture and Record Content
1.00
AU-3Content of Audit Records
1.00

+16 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-217466r961443_chk)

Determine if time zone is configured on the HP FlexFabric Switch: [HP] display clock 15:00:32 EST Thu 07/09/2015 Time Zone : EST minus 05:00:00 Check if info-center is configured to provide timestamp: [HP] display info-center Information Center: Enabled Console: Enabled Monitor: Enabled Log host: Enabled 192.100.50.27, port number: 514, host facility: local7 Log buffer: Enabled Max buffer size 1024, current buffer size 512 Current messages 66, dropped messages 0, overwritten messages 0 Log file: Enabled Security log file: Enabled Information timestamp format: Log host: Date Other output destination: Date Check logfile content to determine if the time stamp is present: <HP> cd logfile/ <HP> more logfile.log %@9377%Jan 20 23:31:03:567 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is dis info-center %@9378%Jan 20 23:31:09:342 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is qui If the HP FlexFabric Switch is not configured to enable timestamp in the log and if time zone is not configurable, this is a finding.

Fix Text (F-18688r293074_fix)

Configure time zone on the HP FlexFabric Switch: [HP] clock timezone EST minus 5:00:00 Configure timestamp on the logs on the HP FlexFabric Switch: [HP] info-center timestamp date Note: By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY.