Network devices must provide a logoff capability for administrator-initiated communication sessions.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-217458 | HFFS-ND-000082 | SV-217458r961224_rule | CCI-002363 | medium |
| Description | ||||
| If an administrator cannot explicitly end a device management session, the session may remain open and be exploited by an attacker; this is referred to as a zombie session. | ||||
| STIG | Date | |||
| HP FlexFabric Switch NDM Security Technical Implementation Guide | 2025-06-12 | |||
Related Frameworks
1 mapping across 3 frameworks
Related Frameworks
SCF0 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (1) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V1R4intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2equal to
NIST 800-530 mappings
No source states a mapping between these directly.
Also reachable in 2 hops (2) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V1R4intersects(normalised)
- DISA STIG Benchmark (XCCDF)1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R4intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
CCI1 mapping
CCI-002363
1.00
- DISA STIG Benchmark (XCCDF)V1R4intersects(normalised)
Details
Check Text (C-217458r961224_chk)
Review the HP FlexFabric Switch configuration to determine if it provides a logoff capability for administrator-initiated communication sessions.
[HP] display users
Idx Line Idle Time Pid Type
+ 177 VTY 0 00:00:00 May 29 15:45:11 1011 SSH
Following are more details.
VTY 0 :
User name: admin@system
Location: 16.117.204.17
+ : Current operation user.
F : Current operation user works in async mode.
If the HP FlexFabric Switch does not provide a logoff capability for these sessions, this is a finding.
Fix Text (F-18680r293050_fix)
Configure the HP FlexFabric Switch to provide a logoff capability for administrator-initiated communication sessions.
[HP] Ctrl + z
<HP> quit