The HP FlexFabric Switch must use internal system clocks to generate time stamps for audit records.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-217447HFFS-ND-000035SV-217447r960927_ruleCCI-000159medium
Description
In order to determine what is happening within the network infrastructure or to resolve and trace an attack, the HP FlexFabric Switch must support the organization's capability to correlate the audit log data from multiple network devices to acquire a clear understanding of events. In order to correlate auditable events, time stamps are needed on all of the log records. If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose. (Note that the internal clock is required to be synchronized with authoritative time sources by other requirements.)
STIGDate
HP FlexFabric Switch NDM Security Technical Implementation Guide2025-06-12

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (15) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(4)Automated Audit Actions
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-6(4)Central Review and Analysis
1.00
AU-7Audit Record Reduction and Report Generation
1.00
AU-7(1)Automatic Processing
1.00

+5 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-217447r960927_chk)

Determine if the HP FlexFabric Switch is configured to use internal system clocks to generate time stamps for audit records. [HP] display clock 06:13:14 MDT Wed 08/05/2015 Time Zone : test minus 05:00:00 Summer Time : MDT 02:00:00 March second Sunday 02:00:00 November first Sunday 01:00:00 If the switch is not configured to use internal system clocks to generate time stamps for audit records, this is a finding.

Fix Text (F-18669r293017_fix)

Configure the HP FlexFabric Switch to use internal system clocks to generate time stamps for audit records. <HP> clock datetime 06:13:00 08/05/2015