The HP FlexFabric Switch must initiate session auditing upon startup.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-217439HFFS-ND-000025SV-217439r960888_ruleCCI-001464low
Description
If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created.
STIGDate
HP FlexFabric Switch NDM Security Technical Implementation Guide2025-06-12

Details

Check Text (C-217439r960888_chk)

Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding.

Fix Text (F-18661r292993_fix)

Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled.