The HP FlexFabric Switch must initiate session auditing upon startup.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-217439 | HFFS-ND-000025 | SV-217439r960888_rule | CCI-001464 | low |
| Description | ||||
| If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created. | ||||
| STIG | Date | |||
| HP FlexFabric Switch NDM Security Technical Implementation Guide | 2025-06-12 | |||
Related Frameworks
2 paths across 2 frameworks
Related Frameworks
NIST 800-531 mapping
AU-14(1)
1.00
- DISA · V1R4 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
CCI1 mapping
CCI-001464
1.00
- DISA · V1R4 · disa_xccdf · related
Details
Check Text (C-217439r960888_chk)
Determine if the info-center feature is enabled on the HP FlexFabric Switch:
[HP] display info-center
Information Center: Enabled
If logging is not enabled, this is a finding.
Fix Text (F-18661r292993_fix)
Enable info-center feature on the HP FlexFabric Switch:
[HP] info-center enable
Note: By default, the information center is enabled.