The HP FlexFabric Switch must enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-217433HFFS-ND-000015SV-217433r960840_ruleCCI-000044medium
Description
By limiting the number of failed logon attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
STIGDate
HP FlexFabric Switch NDM Security Technical Implementation Guide2025-06-12

Details

Check Text (C-217433r960840_chk)

Verify that the HP FlexFabric Switch is configured to enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period. [HP] display password-control Global password control configurations: Maximum login attempts: 3 Action for exceeding login attempts: Lock user for 15 minutes If the limit of three consecutive invalid logon attempts by a user during a 15-minute time period is not enforced, this is a finding.

Fix Text (F-18655r292975_fix)

Configure the HP FlexFabric Switch to enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period: [HP]password-control login-attempt 3 exceed lock-time 15