STIGViewer Support

The operating system must, for networked systems, compare internal information system clocks at least every 24 hours with an authoritative time source.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-203711SRG-OS-000355-GPOS-00143SV-203711r1038944_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIGDate
General Purpose Operating System Security Requirements Guide2024-12-04

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-203711r1038944_chk)

Verify the operating system, for networked systems, compares internal information system clocks at least every 24 hours with an authoritative time source. If it does not, this is a finding.

Fix Text (F-3836r1038943_fix)

Configure the operating system to, for networked systems, compare internal information system clocks at least every 24 hours with an authoritative time source.