STIGViewer Support

Forescout must use FIPS 140-2 approved algorithms for authentication to a cryptographic module.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-230969FORE-NM-000430SV-230969r961050_ruleCCI-000803high
Description
Unapproved mechanisms used for authentication to the cryptographic module are not validated and therefore cannot be relied upon to provide confidentiality or integrity, and DoD data may be compromised. Network devices utilizing encryption are required to use FIPS-compliant mechanisms for authenticating to cryptographic modules. FIPS 140-2 is the current standard for validating that mechanisms used to access cryptographic modules utilize authentication that meets DoD requirements. However, authentication algorithms must configure security processes to use only FIPS-approved and NIST-recommended authentication algorithms.
STIGDate
Forescout Network Device Management Security Technical Implementation Guide2025-06-12

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (7) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-01.2Authenticate, Authorize and Audit (AAA)
1.00
IAC-02Identification & Authentication for Organizational Users
1.00
IAC-03Identification & Authentication for Non-Organizational Users
1.00
IAC-04Identification & Authentication for Devices
1.00
IAC-05Identification & Authentication for Third-Party Technology Assets, Applications and/or Services (TAAS)
1.00
CRY-02Automated Authentication Through Cryptographic Modules
0.50
IAC-12Cryptographic Module Authentication
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (36) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(2)Protection of Confidentiality and Integrity Using Encryption
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-4Information Flow Enforcement
1.00
AC-4(17)Domain Authentication
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-3Content of Audit Records
1.00
CM-5(1)Automated Access Enforcement and Audit Records
1.00

+26 more (top 10 by confidence shown)

CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

7 NICE work roles and 5 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-230969r961050_chk)

Log on using the CLIAdmin credentials established upon initial configuration. Verify FIPS mode by typing the command "fstool version". If Forescout does not use FIPS 140-2 approved algorithms for authentication to a cryptographic module, this is a finding.

Fix Text (F-33872r615884_fix)

To enable FIPS mode on the Forescout appliance, start by opening a secure shell to the CLI of the management appliance using Putty or another tool. Log on using the CLIAdmin credentials established upon initial configuration. To enable FIPS mode, type "fstool fips". At the prompt to alert the user FIPS 140-2 will be enabled, type "Yes" to accept. Note: Use of FIPS mode is not mandatory in DoD. However, it is the primary method for mitigation of this requirement and ensuring FIPS compliance.