STIGViewer Support

Forescout must be configured to synchronize internal information system clocks using redundant authoritative time sources.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-230944FORE-NM-000160SV-230944r1112438_ruleCCI-000366medium
Description
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while the source synchronizes time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.
STIGDate
Forescout Network Device Management Security Technical Implementation Guide2025-06-12

Related Frameworks

3 mappings across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (8) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
CFG-02Secure Baseline Configurations
0.50
CFG-02.7Approved Configuration Deviations
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (100) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-12Session Termination
1.00
AC-16(1)Dynamic Attribute Association
1.00
AC-17(1)Monitoring and Control
1.00
AC-2Account Management
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-24(1)Transmit Access Authorization Information
1.00
AC-25Reference Monitor
1.00

+90 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.1
1.00
3.4.2
1.00
CCI3 mappings
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

PR.PSPlatform Security
0.50

Who does this work

10 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-230944r1112438_chk)

Determine if Forescout is configured to synchronize internal clocks with the organization's primary and secondary NTP servers. Determine if Forescout is configured to synchronize internal clocks with the organization's primary and secondary NTP servers. 1. Open an SSH session and authenticate to the Forescout command line. 2. Verify a primary and secondary NTP server has been configured with the command "fstool ntp test". Or 1. Open the Forescout console. 2. Navigate to General >> Time and verify "Enable sync with NTP server" is checked. If Forescout is not configured to synchronize internal information system clocks with the organization's primary and secondary NTP servers, this is a finding.

Fix Text (F-33847r1112437_fix)

Configure Forescout to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. 1. Open an SSH session and authenticate to the Forescout command line. 2. Configure the primary and secondary NTP servers with the command "fstool ntp setup <ip address>". or 1. Open the Forescout console. 2. Navigate to General >> Time. 3. Check the box for "Enable sync with NTP server".