STIGViewer Support

The Forescout must configure a remote syslog where audit records are stored on a centralized logging target that is different from the system being audited.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-230943FORE-NM-000150SV-230943r1111869_ruleCCI-001851low
Description
Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading is a common process in information systems with limited audit storage capacity.
STIGDate
Forescout Network Device Management Security Technical Implementation Guide2025-06-12

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-08.1Event Log Backup on Separate Physical Systems / Components
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (34) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(1)System-wide and Time-correlated Audit Trail
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00

+24 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-230943r1111869_chk)

Verify the syslog. 1. Log on to Forescout Administrator UI with admin or operator credentials. 2. From the menu, select Tools >> Options >> Modules >> Syslog >> Send Events To. 3. Click the IP address of the site's centralized syslog server. 4. Verify Identity, Facility, and Severity, as required by the SSP, are configured. If the site's syslog server is not configured, this is a finding.

Fix Text (F-33846r1111868_fix)

Configure the syslog. 1. Log on to Forescout Administrator UI with admin or operator credentials. 2. From the menu, select Tools >> Options >> Modules >> Syslog >> Send Events To. 3. Click "Add". 4. Enter the IP address of the site's centralized syslog. 5. Configure Identity, Facility, and Severity as required by the SSP.