Forescout must generate a critical alert to be sent to the Information System Security Officer (ISSO) and Systems Administrator (SA) (at a minimum) in the event of an audit processing failure. This is required for compliance with C2C Step 1.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-233325FORE-NC-000170SV-233325r1113798_ruleCCI-001858medium
Description
Ensuring that a security solution alerts in the event of misconfiguration or error is imperative to ensuring that proper auditing is being conducted. Having the ability to immediately notify an administrator when this auditing fails allows for a quick response and real-time remediation.
STIGDate
Forescout Network Access Control Security Technical Implementation Guide2025-06-12

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-05.1Real-Time Alerts of Event Logging Failure
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (22) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(4)Automated Audit Actions
1.00
AU-12Audit Record Generation
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-4Audit Log Storage Capacity
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-5(1)Storage Capacity Warning
1.00
AU-5(2)Real-time Alerts
1.00

+12 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-233325r1113798_chk)

If DOD is not at C2C Step 1 or higher, this is not a finding. Verify Forescout sends an alert to the proper security personnel when an audit process failure occurs. 1. Log on to the Forescout UI. 2. Locate the audit process policies as identified by the site representative. 3. Verify a policy for "audit failure" exists. 4. Verify this policy includes notification of security personnel as follows. a. Navigate to Options >> General >> Mail and DNS. b. Verify the configuration of the appropriate Operator Email and mail relay information to ensure alerts and notifications are being sent to the appropriate people. c. Verify that any policies that need notification actions have one of the following actions configured: - Send Email. - Send Email to User. - Send Balloon Notification. - HTTP Notification. - Splunk: Send Update from CounterACT. If Forescout does not send an alert when an audit processing failure occurs, this is a finding.

Fix Text (F-36485r1111897_fix)

Log on to the Forescout UI. 1. Locate the audit process policies as identified by the site representative. 2. Configure a policy for audit failure to include the notification of security personnel. This could also include sending a balloon message, notification, or email as follows. a. Navigate to Options >> General >> Mail and DNS. b. Configure the appropriate Operator Email and mail relay information to ensure alerts and notifications are being sent to the appropriate people. c. Additionally, ensure that any policies that need notification actions have one of the following actions configured: - Send Email. - Send Email to User. - Send Balloon Notification. - HTTP Notification. - Splunk: Send Update from CounterACT.