STIGViewer Support

The EDB Postgres Advanced Server must provide an immediate real-time alert to appropriate support staff of all audit log failures.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-259280EPAS-00-008100SV-259280r961401_ruleCCI-001858medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. The appropriate support staff include, at a minimum, the ISSO and the DBA/SA. A failure of database auditing will result in either the database continuing to function without auditing or in a complete halt to database operations. When audit processing fails, appropriate personnel must be alerted immediately to avoid further downtime or unaudited transactions. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).
STIGDate
EnterpriseDB Postgres Advanced Server (EPAS) Security Technical Implementation Guide2026-09-03

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-05.1Real-Time Alerts of Event Logging Failure
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (23) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AU-12Audit Record Generation
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-4Audit Log Storage Capacity
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-5(1)Storage Capacity Warning
1.00

+13 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-259280r961401_chk)

Review Postgres Enterprise Manager (PEM) alert settings, OS, or third-party logging software settings to determine whether a real-time alert will be sent to the appropriate personnel when auditing fails for any reason. If real-time alerts are not sent upon auditing failure, this is a finding.

Fix Text (F-62928r938892_fix)

Install PEM and configure audit failure event alerting as documented here: https://www.enterprisedb.com/docs/pem/latest/ An example for creating an alert that ensure the audit directory does not fill up is included below, using the thin client (browser) PEM interface. Refer also to the Supplemental Procedures document supplied with this STIG. Open the PEM web console in a browser. - Log in. - Click on the agent for the machine to be monitored. - Select "Management | Probe Configuration". - Select "Disk Space" and set the check interval as warranted. - Select "Management | Alerting". - Name the definition "Audit Log Full". - Select Template "Disk Consumption Percentage". - Set Frequency, Comparison Operator, and Thresholds (1 minute, >, 95/96/97 for example). - Enter the Mount Point for where the audit log is. - Click Notification tab. - Click Email all alerts. - Click "Execute Script" on Monitored Server.