STIGViewer Support

The A/B, A/B/C, or A/B/C/D switch used for network switching in IP-based VTC systems implementing a single CODEC that supports conferences on multiple networks with different classification levels must be TEMPEST certified.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-259899SRG-VOIP-000190SV-259899r1173870_ruleCCI-002212low
Description
Committee on National Security Systems Advisory Memorandum (CNSSAM) TEMPEST/01-13, RED/BLACK Installation Guidance, provides criteria for the installation of electronic equipment, cabling, and facility support for the processing of secure information. National policy requires that systems and facilities processing NSI must be reviewed by a Certified TEMPEST Technical Authority (CTTA) to achieve TEMPEST security. The RED/BLACK guidance contained in TEMPEST/01-13 will be considered by the CTTA along with other measures (e.g., TEMPEST Zoning, TEMPEST-suppressed equipment and shielding) to determine the most cost-effective countermeasures to achieve TEMPEST security. Only those RED/BLACK criteria specifically identified by the CTTA will be implemented.
STIGDate
Enterprise Voice, Video, and Messaging Policy Security Requirements Guide2025-12-23

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

NET-04.11Approved Solutions
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-4(20)Approved Solutions
1.00
CCI1 mapping

Details

Check Text (C-259899r1173870_chk)

Review the documentation to determine if the A/B, A/B/C, or A/B/C/D switch is TEMPEST certified. Review TEMPEST certification documentation provided by a CTTA or the vendor to determine if the switch is TEMPEST certified. If the A/B, A/B/C, or A/B/C/D switch is not on the list, or satisfactory documentation is not provided, this is a finding.

Fix Text (F-63537r946617_fix)

Obtain and install a TEMPEST-certified A/B, A/B/C, or A/B/C/D switch.