STIGViewer Support

The Cisco Multicast Source Discovery Protocol (MSDP) switch must be configured to use a loopback address as the source address when originating MSDP traffic.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-221147CISC-RT-000950SV-221147r999776_ruleCCI-004931low
Description
Using a loopback address as the source address offers a multitude of uses for security, access, management, and scalability of MSDP switches. It is easier to construct appropriate ingress filters for switch management plane traffic destined to the network management subnet since the source addresses will be from the range used for loopback interfaces instead of a larger range of addresses used for physical interfaces. Log information recorded by authentication and syslog servers will record the switch’s loopback address instead of the numerous physical interface addresses.
STIGDate
Cisco NX OS Switch RTR Security Technical Implementation Guide2026-03-04

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

BCD-10.4Alternate Communications Channels
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

SC-47Alternate Communications Paths
1.00
SC-5(2)Capacity, Bandwidth, and Redundancy
1.00
SC-7Boundary Protection
1.00
SC-7(11)Restrict Incoming Communications Traffic
1.00
SC-7(29)Separate Subnets to Isolate Functions
1.00
CCI1 mapping

Details

Check Text (C-221147r999776_chk)

Step 1: Review the switch configuration to verify that a loopback address has been configured. interface Loopback12 ip address x.12.2.2/32 Step 2: Verify that the loopback interface is used as the source address for all MSDP packets generated by the switch. ip msdp peer x.44.2.34 connect-source Loopback12 remote-as nn If the switch does not use its loopback address as the source address when originating MSDP traffic, this is a finding.

Fix Text (F-22851r409931_fix)

Configure the switch to use its loopback address is used as the source address when sending MSDP packets. SW1(config)# ip msdp peer x.44.2.34 connect-source lo12 remote-as nn