The Cisco Multicast Source Discovery Protocol (MSDP) switch must be configured to use a loopback address as the source address when originating MSDP traffic.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-221069CISC-RT-000950SV-221069r622190_ruleCCI-000366low
Description
Using a loopback address as the source address offers a multitude of uses for security, access, management, and scalability of MSDP switches. It is easier to construct appropriate ingress filters for switch management plane traffic destined to the network management subnet since the source addresses will be from the range used for loopback interfaces instead of a larger range of addresses used for physical interfaces. Log information recorded by authentication and syslog servers will record the switch’s loopback address instead of the numerous physical interface addresses.
STIGDate
Cisco IOS XE Switch RTR Security Technical Implementation Guide2026-03-04

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (8) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
CFG-02Secure Baseline Configurations
0.50
CFG-02.7Approved Configuration Deviations
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (100) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-12Session Termination
1.00
AC-16(1)Dynamic Attribute Association
1.00
AC-17(1)Monitoring and Control
1.00
AC-2Account Management
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-24(1)Transmit Access Authorization Information
1.00
AC-25Reference Monitor
1.00

+90 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.1
1.00
3.4.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

PR.PSPlatform Security
0.50

Who does this work

10 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-221069r622190_chk)

Step 1: Review the switch configuration to verify that a loopback address has been configured. interface Loopback12 ip address x.12.2.2 255.255.255.255 Step 2: Verify that the loopback interface is used as the source address for all MSDP packets generated by the switch. ip msdp peer x.44.2.34 connect-source Loopback12 remote-as nn If the switch does not use its loopback address as the source address when originating MSDP traffic, this is a finding.

Fix Text (F-22773r409002_fix)

Configure the switch to use its loopback address is used as the source address when sending MSDP packets. SW2(config)#ip msdp peer x.44.2.34 connect-source lo12 remote-as nn