The Cisco switch must be configured to synchronize its clock with the primary and secondary time sources using redundant authoritative time sources.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-220549CISC-ND-001030SV-220549r991924_ruleCCI-001889medium
Description
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.
STIGDate
Cisco IOS XE Switch NDM Security Technical Implementation Guide2025-05-19

Details

Check Text (C-220549r991924_chk)

Review the Cisco switch configuration to verify that it is compliant with this requirement as shown in the configuration example below: ntp server x.x.x.x ntp server y.y.y.y If the Cisco switch is not configured to synchronize its clock with redundant authoritative time sources, this is a finding.

Fix Text (F-22253r508592_fix)

Configure the Cisco switch to synchronize its clock with redundant authoritative time sources as shown in the example below: SW2(config)#ntp server x.x.x.x SW2(config)#ntp server y.y.y.y