STIGViewer Support

The Cisco PE router providing MPLS Virtual Private Wire Service (VPWS) must be configured to have the appropriate virtual circuit identification (VC ID) for each attachment circuit.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-216705CISC-RT-000670SV-216705r991900_ruleCCI-004931high
Description
VPWS is an L2VPN technology that provides a virtual circuit between two PE routers to forward Layer 2 frames between two customer-edge routers or switches through an MPLS-enabled IP core. The ingress PE router (virtual circuit head-end) encapsulates Ethernet frames inside MPLS packets using label stacking and forwards them across the MPLS network to the egress PE router (virtual circuit tail-end). During a virtual circuit setup, the PE routers exchange VC label bindings for the specified VC ID. The VC ID specifies a pseudowire associated with an ingress and egress PE router and the customer-facing attachment circuits. To guarantee that all frames are forwarded onto the correct pseudowire and to the correct customer and attachment circuits, it is imperative that the correct VC ID is configured for each attachment circuit.
STIGDate
Cisco IOS XE Router RTR Security Technical Implementation Guide2025-08-14

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

BCD-10.4Alternate Communications Channels
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

SC-47Alternate Communications Paths
1.00
SC-5(2)Capacity, Bandwidth, and Redundancy
1.00
SC-7Boundary Protection
1.00
SC-7(11)Restrict Incoming Communications Traffic
1.00
SC-7(29)Separate Subnets to Isolate Functions
1.00
CCI1 mapping

Details

Check Text (C-216705r991900_chk)

Verify that the correct and unique VCID has been configured for the appropriate attachment circuit. In the example below, GigabitEthernet0/1 is the CE-facing interface that is configured for VPWS with the VCID of 55. interface GigabitEthernet0/1 xconnect x.2.2.12 55 encapsulation mpls If the correct VC ID has not been configured on both routers, this is a finding.

Fix Text (F-17936r288061_fix)

Assign globally unique VC IDs for each virtual circuit and configure the attachment circuits with the appropriate VC ID. R5(config)#int g0/1 R5(config-if)#xconnect x.2.2.12 55 encapsulation mpls