STIGViewer Support

The Central Log Server must compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-263585SRG-APP-000925-AU-000420SV-263585r982451_ruleCCI-004923medium
Description
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
STIGDate
Central Log Server Security Requirements Guide2024-12-04

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-263585r982451_chk)

Verify the Central Log Server is configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. If the Central Log Server is not configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source, this is a finding.

Fix Text (F-67393r981839_fix)

Configure the Central Log Server to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.