Analysis, viewing, and indexing functions, services, and applications used as part of the Central Log Server must be configured to comply with DoD-trusted path and access requirements.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-206518SRG-APP-000516-AU-000410SV-206518r961863_ruleCCI-000366medium
Description
Analysis, viewing, and indexing functions, services, and applications, such as analysis tools and other vendor-provided applications, must be secured. Software used to perform additional functions, which resides on the server, must also be secured or could provide a vector for unauthorized access to the events repository.
STIGDate
Central Log Server Security Requirements Guide2024-12-04

Related Frameworks

4 paths across 3 frameworks
NIST 800-531 mapping
CM-6
1.00
  • DISA · 3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.4.1
1.00
  • DISA · 3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.4.2
1.00
  • DISA · 3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000366
1.00
  • DISA · 3 · disa_xccdf · related

Details

Check Text (C-206518r961863_chk)

Examine the configuration. Verify analysis, viewing, and indexing functions, services, and applications used with the Central Log Server are configured to comply with DoD-trusted path and access requirements. If analysis, viewing, and indexing functions, services, and applications used with the Central Log Server are not configured to comply with DoD-trusted path and access requirements, this is a finding.

Fix Text (F-6778r285796_fix)

Configure all analysis, viewing, and indexing functions, services, and applications used with the Central Log Server to comply with DoD-trusted path and access requirements.