The Central Log Server must be configured to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-206505SRG-APP-000375-AU-000280SV-206505r961446_ruleCCI-001889low
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks. Note: The actual configuring and security requirements for NTP is handled in the host OS or NDM STIGs that are also required as part of a Central Log Server review.
STIGDate
Central Log Server Security Requirements Guide2024-12-04

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (30) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-14(2)Capture and Record Content
1.00
AU-3Content of Audit Records
1.00

+20 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-206505r961446_chk)

Examine the configuration. Verify the Central Log Server records time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision. If the Central Log Server is not configured to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision, this is a finding.

Fix Text (F-6765r285757_fix)

Configure the Central Log Server to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.