STIGViewer Support

Ax-OS must compare the internal system clocks on an organization-defined frequency with an organization-defined authoritative time source.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-276016AXOS-00-000080SV-276016r1123260_ruleCCI-004923medium
Description
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network. Satisfies: SRG-APP-000925, SRG-APP-000371, SRG-APP-000372, SRG-APP-000374, SRG-APP-000920
STIGDate
Axonius Federal Systems Ax-OS Security Technical Implementation Guide2025-11-25

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-276016r1123260_chk)

From the Axonius Toolbox (accessed via Secure Shell [SSH]) Main Actions Menu, select the following options: System Actions >> Advanced System Actions >> NTP Sources If any NTP sources listed are not an authoritative time source approved by the authorizing official (AO), this is a finding.

Fix Text (F-80059r1123241_fix)

From the Axonius Toolbox (accessed via SSH) Main Actions Menu, select the following options: System Actions >> Advanced System Actions >> Configure NTP Enter the hostname/IP of an AO-approved authoritative time source.