Compliance Guardian must initiate a session timeout after a 15-minute period of inactivity.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-256840 | APCG-00-000005 | SV-256840r890130_rule | CCI-000057 | medium |
| Description | ||||
| A session time-out lock is a temporary action taken when a user stops work and moves away from the immediate physical vicinity of the information system but does not log out because of the temporary nature of the absence. Rather than relying on the user to manually lock their application session prior to vacating the vicinity, applications must identify when a user's session has idled and initiate the session lock. The session lock is implemented at the point where session activity can be determined and/or controlled. This is typically at the operating system level and results in a system lock but may be at the application level where the application interface window is secured instead. | ||||
| STIG | Date | |||
| AvePoint Compliance Guardian Security Technical Implementation Guide | 2023-02-21 | |||
Related Frameworks
1 mapping across 4 frameworks
Related Frameworks
SCF0 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (1) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
NIST 800-530 mappings
No source states a mapping between these directly.
Also reachable in 2 hops (18) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R4our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R4intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)1our copyintersects(normalised)DISA STIG Benchmark (XCCDF)V1R7our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)1intersects(normalised)DISA STIG Benchmark (XCCDF)V1R7intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)7our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)7intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
+8 more (top 10 by confidence shown)
NIST 800-1710 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (1) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
3.1.10
1.00
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
CCI1 mapping
CCI-000057
1.00
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
Details
Check Text (C-256840r890130_chk)
Check the Compliance Guardian Manager Session Timeout setting.
- Log on to Compliance Guardian with admin account.
- On the Control Panel page, in the System Configuration section, click "General Settings".
- Select "Security - System Security Policy".
- Verify the "Please specify a session time-out value". The user will be logged off automatically if there is no activity for the specified period. Logon will expire in option.
If the session timeout value is not set to 15 minutes or less, this is a finding.
Fix Text (F-60458r890129_fix)
Configure the Compliance Guardian Manager Session Timeout setting.
- Log on to Compliance Guardian with admin account.
- On the Control Panel page, in the System Configuration section, click "General Settings".
- Select "Security - System Security Policy".
- Set 15 minutes or less in the "Please specify a session time-out value". The user will be logged off automatically if there is no activity for the specified period. Logon will expire in option.
- Save the settings.