STIGViewer Support

The application must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-222499APSC-DV-001270SV-222499r961446_ruleCCI-001889medium
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
STIGDate
Application Security and Development Security Technical Implementation Guide2026-08-25

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (30) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-14(2)Capture and Record Content
1.00
AU-3Content of Audit Records
1.00

+20 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-222499r961446_chk)

Review the system documentation and interview the application administrator to determine where application audit logs are written and how time stamps are recorded. If the application utilizes the underlying OS for time stamping and time synchronization when writing the audit logs, this requirement is not applicable. Access and review log files over a period of at least 10 minutes; compare time stamps written in the application log to the system clock to ensure time is synchronized to within 1 second of precision. If the application audit log time stamps differ from the OS time source by more than one second, this is a finding.

Fix Text (F-24158r493406_fix)

Configure the application to leverage the underlying operating system as the time source when recording time stamps or design the application to ensure granularity of 1 second as the minimum degree of precision.