STIGViewer Support

The application must log user actions involving access to data.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-222471APSC-DV-000960SV-222471r960891_ruleCCI-000130medium
Description
When users access application data, there is risk of data compromise or seepage if the account used to access is compromised or access is granted improperly. To be able to investigate which account accessed data, the account access must be logged. Without establishing when the access event occurred, it would be difficult to establish, correlate, and investigate the events relating to an incident, or identify those responsible for one. Associating event types with detected events in the application and audit logs provides a means of investigating an attack; recognizing resource utilization or capacity thresholds; or identifying an improperly configured application.
STIGDate
Application Security and Development Security Technical Implementation Guide2026-08-25

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-01Continuous Monitoring
1.00
MON-01.4System Generated Alerts
1.00
MON-03Content of Event Logs
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (46) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-3(3)Mandatory Access Control
1.00
AC-4Information Flow Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-10Non-repudiation
1.00

+36 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.1
1.00
3.3.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

6 NICE work roles and 5 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-222471r960891_chk)

Review and monitor the application logs. When accessing data, the logs are most likely database logs. If the application design documents include specific data elements that require protection, ensure user access to those data elements are logged. Utilize the application as a regular user and operate the application so as to access data elements contained within the application. This includes using the application user interface to browse through data elements, query/search data elements and using report generation capability if it exists. Observe and determine if the application log includes an entry to indicate the user’s access to the data was recorded. If successful access to application data elements is not recorded in the logs, this is a finding.

Fix Text (F-24130r493322_fix)

Identify the specific data elements requiring protection and audit access to the data.