Amazon Linux 2023 must audit all uses of the shutdown command.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-274100AZLX-23-002185SV-274100r1120288_ruleCCI-000172medium
Description
Misuse of the shutdown command may cause availability issues for the system.
STIGDate
Amazon Linux 2023 Security Technical Implementation Guide2026-02-27

Related Frameworks

4 paths across 3 frameworks
NIST 800-531 mapping
AU-12
1.00
  • DISA · V1R3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.3.1
1.00
  • DISA · V1R3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.3.2
1.00
  • DISA · V1R3 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000172
1.00
  • DISA · V1R3 · disa_xccdf · related

Details

Check Text (C-274100r1120288_chk)

Verify Amazon Linux 2023 is configured to audit the execution of the "shutdown" command with the following command: $ sudo auditctl -l | grep shutdown -a always,exit -F path=/usr/sbin/shutdown -F perm=x -F auid>=1000 -F auid!=unset -k privileged-shutdown If the command does not return a line, or the line is commented out, this is a finding.

Fix Text (F-78096r1120287_fix)

Configure Amazon Linux 2023 so that the audit system generates an audit event for any successful/unsuccessful uses of the "shutdown" command by adding or updating the following rule in the "/etc/audit/rules.d/audit.rules" file: -a always,exit -F path=/usr/sbin/shutdown -F perm=x -F auid>=1000 -F auid!=unset -k privileged-shutdown To load the rules to the kernel immediately, use the following command: $ sudo augenrules --load