STIGViewer Support

ColdFusion must record time stamps for log records that can be mapped system time.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-279077APAS-CF-000640SV-279077r1171570_ruleCCI-001890medium
Description
Using a consistent time standard such as UTC or GMT for the internal clock of ColdFusion is crucial for maintaining accurate and reliable system logs. This consistency is essential for correlating events across different systems and networks, especially in environments where systems are geographically dispersed. If the internal clock is not set to a standard time, it can lead to discrepancies in log files, making it difficult to trace and investigate security incidents. Additionally, using a nonstandard time setting can complicate the synchronization of time-sensitive operations and affect the overall security posture of ColdFusion. Therefore, setting the internal clock to UTC or GMT helps ensure the integrity and reliability of system logs and enhances the ability to detect and respond to security events effectively.
STIGDate
Adobe ColdFusion Security Technical Implementation Guide2025-12-19

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (26) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(9)Disconnect or Disable Access
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-14(2)Capture and Record Content
1.00
AU-3Content of Audit Records
1.00

+16 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-279077r1171570_chk)

Verify JVM Arguments for Time zone. From the Admin Console Landing Screen, navigate to Server Settings >> Java and JVM. If the JVM argument -"Duser.timezone=<TIMEZONE>" cannot be found , this is a finding.

Fix Text (F-83530r1171569_fix)

Configure JVM Arguments for Time zone. 1. From the Admin Console Landing Screen, navigate to Server Settings >> Java and JVM. 2. Add the argument as: "Duser.timezone=<TIMEZONE>" (If the parameter is already defined, change the setting to "<TIMEZONE>".) 3. Select "Submit Changes".