AAA Services must be configured to enforce 24 hours as the minimum password lifetime.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-204673 | SRG-APP-000173-AAA-000530 | SV-204673r981570_rule | CCI-004066 | medium |
| Description | ||||
| Enforcing a minimum password lifetime helps prevent repeated password changes to defeat the password reuse or history enforcement requirement. Restricting this setting limits the user's ability to change their password. Passwords need to be changed at specific policy based intervals; however, if the application allows the user to immediately and continually change their password, then the password could be repeatedly changed in a short period of time to defeat the organization's policy regarding password reuse. | ||||
| STIG | Date | |||
| AAA Services Security Requirements Guide | 2026-09-01 | |||
Related Frameworks
1 mapping across 4 frameworks
Related Frameworks
SCF0 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (3) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
NIST 800-530 mappings
No source states a mapping between these directly.
Also reachable in 2 hops (63) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)9our copyintersects(normalised)DISA STIG Benchmark (XCCDF)V9R9our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)9intersects(normalised)DISA STIG Benchmark (XCCDF)V9R9intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
+53 more (top 10 by confidence shown)
NIST 800-1710 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (4) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
3.5.10
1.00
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
3.5.7
1.00
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
3.5.8
1.00
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
3.5.9
1.00
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- NIST SP 800-171 Rev 2, Appendix DRev 2 (Feb 2020, errata Jan 2021)equal to(normalised)
CCI1 mapping
CCI-004066
1.00
- DISA STIG Benchmark (XCCDF)V2R3intersects(normalised)
Details
Check Text (C-204673r981570_chk)
If AAA Services rely on directory services for user account management, this is not applicable and the connected directory services must perform this function. This requirement is not applicable to service account passwords (e.g., shared secrets, pre-shared keys) or the account of last resort.
Where passwords are used, such as temporary or emergency accounts, verify AAA Services are configured to enforce 24 hours as the minimum password lifetime. When the AAA Services configuration setting is for "1 day", it is required that the length be 24 hours.
If AAA Services are not configured to enforce 24 hours as the minimum password lifetime, this is a finding.
Fix Text (F-4796r981569_fix)
Configure AAA Services to enforce 24 hours as the minimum password lifetime. When the AAA Services configuration setting is for "1 day", it is required that the length be 24 hours. This requirement is not applicable to service account passwords (e.g., shared secrets, pre-shared keys) or the account of last resort.