Back to catalog
BCD-09.2BCDBusiness Continuity & Disaster Recovery
Alternate Processing Site Accessibility
Description
Mechanisms exist to identify and mitigate potential accessibility problems to the alternate processing sites and possible mitigation actions, in the event of an area-wide disruption or disaster.
Cross-Mappings
27 paths across 3 frameworks
Cross-Mappings
NIST 800-531 mapping
CP-7(2)
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
CCI2 mappings
CCI-000517
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
CCI-001606
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
STIG12 mappings
SV-259911r948757_ruleThe LAN hardware supporting VVoIP services must provide redundancy to support command and control (C2) assured services and Fire and Emergency Services (FES) communications.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259912r948758_ruleThe LAN hardware supporting VVoIP services must provide physically diverse pathways for redundant links supporting command and control (C2) assured services and Fire and Emergency Services (FES) communications.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259913r948759_ruleThe site's enclave boundary protection must route commercial VoIP traffic via a local Media Gateway (MG) connected to a commercial service provider using PRI, CAS, or POTS analog trunks.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259914r948760_ruleLocal commercial phone service must be provided in support of continuity of operations (COOP) and Fire and Emergency Services (FES) communications.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259918r948764_ruleCritical network equipment must be redundant and in geographically diverse locations for a site supporting command and control (C2) users.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259919r948765_ruleEnclaves with commercial VoIP connections must be approved by the DODIN Waiver Panel and signed by DOD CIO for a permanent alternate connection to the Internet Telephony Service Provider (ITSP).
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259920r948766_ruleThe Fire and Emergency Services (FES) communications over a site's telephone system must be configured to support the Department of Defense Instruction (DODI) 6055.06 telecommunication capabilities.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259921r948767_ruleThe Fire and Emergency Services (F&ES) communications over a site's private telephone system must provide the originating telephone number to the emergency services answering point or call center through a transfer of Automatic Number Identification (ANI) or Automatic Location Identification (ALI) information.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259922r948768_ruleThe Fire and Emergency Services (F&ES) communications over a site's private telephone system must provide a direct callback telephone number and physical location of an F&ES caller to the emergency services answering point or call center through a transfer of Automatic Number Identification (ANI) and extended Automatic Location Identification (ALI) information or access to an extended ALI database.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
SV-259923r948769_ruleThe Fire and Emergency Services (F&ES) communications over a site's private telephone system must route emergency calls as a priority call in a nonblocking manner.
1.00
- Secure Controls Framework · 2026.2 · scf_strm · equivalent
- DISA · 2025-01-23 · disa_cci_list · equivalent
- DISA · 1 · disa_xccdf · related
+2 more (top 10 by confidence shown)
Control mappings provided by the Secure Controls Framework (SCF).
SCF
Powered by the Secure Controls Framework
The control catalog, cross-mappings, and STRM relationship data shown here are provided by the Secure Controls Framework (SCF), 2026.2. Every mapping is credited to SCF as the methodology, with the SCF reference and version stored alongside it.
© SCF Council, LLC. Secure Controls Framework content is free and shown here with attribution. securecontrolsframework.com · About SCF on STIGViewer