UCF STIG Viewer Logo

Tivoli Asset Discovery for zOS (TADz) STC and/or batch data sets are not properly protected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17067 ZTADA001 SV-28547r1_rule DCSL-1 ECAR-1 ECAR-2 ECAR-3 ECCD-1 ECCD-2 Medium
Description
Tivoli Asset Discovery for zOS (TADz) STC data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to their data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
STIG Date
z/OS TADz for ACF2 STIG 2016-01-04

Details

Check Text ( C-29337r1_chk )
a) Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(TADZSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZTAD0001)

b) Verify that acess to the TADz STC and/or batch data sets are properly restricted.

___ The ACF2 data set rules for the data sets does not restrict UPDATE and/or ALTER access to systems programming personnel.

___ The ACF2 data set rules for the data sets does not restrict UPDATE and/or ALTER access to the product STC(s) and/or batch job(s).

c) If all of the above are untrue, there is NO FINDING.

d) If any of the above is true, this is a FINDING.
Fix Text (F-26941r1_fix)
The IAO will ensure that update and alter access to Tivoli Asset Discovery for zOS (TADz) STC and/or batch data sets are limited to system programmers and TADz STC and/or batch jobs only. Read access may be granted to auditors at the IAOs discretion.

The installing systems programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program ) active on the system.

Data sets to be protected will be:
SYS3.TADZ

The following commands are provided as a sample for implementing dataset controls:

$KEY(SYS3)
TADZ.- UID(syspaudt) R(A) W(A) A(A) E(A)
TADZ.- UID(audtaudt) R(A) E(A)
TADZ.-.UM.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A)
TADZ.-.IQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A)
TADZ.-.UIQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A)
TADZ.- UID(stc id TADZMON) R(A) W(A) A(A) E(A)