CL/SuperSession's Resouce Class is not defined or active in the ACP.


Overview

Finding ID Version Rule ID IA Controls Severity
V-18011 ZCLST038 SV-27190r1_rule DCCS-1 DCCS-2 Medium
Description
Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS operating system and user data.
STIG Date
z/OS CL/SuperSession for TSS STIG 2015-03-30

Details

Check Text ( C-20144r1_chk )
a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#RDT)

b) If the resource class of KLS is defined, there is NO FINDING.

c) If the resource class of KLS is not defined, this is a FINDING.
Fix Text (F-6661r1_fix)
Add the resource KLS to the TOP SECRET RDT using the following TSS command example:

TSS ADD(RDT) RESCLASS(KLS) RESCODE(xx)

(where xx is an unused hex value)