Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-70513 | HP3P-32-001700 | SV-85135r1_rule | Medium |
Description |
---|
To verify operating systems have a sufficient storage capacity in which to write the audit logs, operating systems need to be able to allocate audit record storage capacity. The task of allocating audit record storage capacity is usually performed during initial installation of the operating system. |
STIG | Date |
---|---|
HPE 3PAR StoreServ 3.2.x Security Technical Implementation Guide | 2017-01-06 |
Check Text ( C-70913r1_chk ) |
---|
Verify the logging capacity is set to the maximum value of "4", with the following command: cli% showsys -param If the resulting list of configured parameters and values, does not contain "EventLogSize : 4M", this is a finding. |
Fix Text (F-76751r1_fix) |
---|