Forescout must send an alert to the Information System Security Manager (ISSM) and System Administrator (SA), at a minimum, when critical security issues are found that put the network at risk. This is required for compliance with C2C Step 2.


Overview

Finding ID Version Rule ID IA Controls Severity
V-233316 FORE-NC-000080 SV-233316r811381_rule Medium
Description
Requiring authentication and authorization of both the user's identity and the identity of the computing device is essential to ensuring a non-authorized person or device has entered the network.
STIG Date
Forescout Network Access Control Security Technical Implementation Guide 2021-12-17

Details

Check Text ( C-36511r811380_chk )
If DoD is not at C2C Step 2 or higher, this is not a finding.

Verify Forescout performs device authentication before policy assessment is performed.

If device authentication is not completed prior to the NAC check, this is a finding.
Fix Text (F-36476r605652_fix)
Log on to the Forescout UI.

1. Locate the Authentication & Authorization policy.
2. Ensure the Authentication & Authorization policy happens prior to any NAC check.