CA IDMS CV must supply logout functionality to allow the user to implicitly terminate a session by disconnecting or ending before an explicit logout.


Overview

Finding ID Version Rule ID IA Controls Severity
V-251633 IDMS-DB-000620 SV-251633r855271_rule Medium
Description
If a user cannot explicitly end a DBMS session, the session may remain open and be exploited by an attacker; this is referred to as a zombie session. Such logouts may be explicit or implicit. Examples of explicit logouts are: clicking on a "Log Out" link or button in the application window; clicking the Windows Start button and selecting "Log Out" or "Shut Down." Examples of implicit logouts are: closing the application's (main) window; powering off the workstation without invoking the OS shutdown. Both the explicit and implicit logouts must be detected by the DBMS. In all cases, the DBMS must ensure that the user's DBMS session and all processes owned by the session are terminated. This should not, however, interfere with batch processes/jobs initiated by the user during their online session: these should be permitted to run to completion. IDMS must provide a facility by which an inactive user session may be terminated after a predetermined period of time.
STIG Date
CA IDMS Security Technical Implementation Guide 2022-09-07

Details

Check Text ( C-55068r807764_chk )
Use TASK SYSGEN if online, or program RHDCSGEN if batch.

Sign on to the dictionary where the System definition is maintained: "SIGNON DICTIONARY SYSTEM.", for example.

Enter: "DISPLAY SYSTEM 123." where 123 is the number of the system being checked.

Scroll through the returned text until "INACTIVE INTERVAL" is found.

If the associated value is not the organization-defined timeout number of wall-clock seconds, this is a finding.

Scroll through the returned text until "RUNAWAY INTERVAL" is found.

If the associated value is not the organization-defined timeout number of wall-clock seconds, this is a finding.
Fix Text (F-55022r807765_fix)
Use TASK SYSGEN if online, or program RHDCSGEN if batch.

Sign on to the dictionary where the system definition is maintained: "SIGNON DICTIONARY SYSTEM.", for example.

Enter: "MODIFY SYSTEM 123 INACTIVE INTERVAL is ." where 123 is the number of the system being modified.

Enter: "MODIFY SYSTEM 123 RUNAWAY INTERVAL is ." where 123 is the number of the system being modified.

Enter: "GENERATE."

The change will become effective the next time the CV is stopped and started.

Note: The system INACTIVE INTERVAL can be overridden with the INACTIVE INTERVAL TASK parameters, e.g., for task RHDCNP3S which services external tasks/sessions.

Note: The UCFCICZ interface may also be used to clean up the CA IDMS session if access is through CICS and the CICS session has ended.