UCF STIG Viewer Logo

The VMM must, for networked systems, compare internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant United States Naval Observatory (USNO) time servers or a time server designated for the appropriate DoD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS).


Overview

Finding ID Version Rule ID IA Controls Severity
V-207463 SRG-OS-000355-VMM-001330 SV-207463r878143_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal VMM clocks provides uniformity of time stamps for VMMs with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIG Date
Virtual Machine Manager Security Requirements Guide 2023-09-12

Details

Check Text ( C-7720r878141_chk )
Verify the VMM, for networked systems, compares internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant United States Naval Observatory (USNO) time servers or a time server designated for the appropriate DoD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS).

If it does not, this is a finding.
Fix Text (F-7720r878142_fix)
Configure the VMM, for networked systems, to compare internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant United States Naval Observatory (USNO) time servers or a time server designated for the appropriate DoD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS).