Nutanix AOS must be configured to send Cluster Check alerts to the SA and ISSO.


Overview

Finding ID Version Rule ID IA Controls Severity
V-254105 NUTX-AP-000150 SV-254105r846403_rule Medium
Description
Logs are essential to monitor the health of the system, investigate changes that occurred to the system, or investigate a security incident. When log processing fails, the events during the failure can be lost. To minimize the timeframe of the log failure, an alert needs to be sent to the SA and ISSO at a minimum. Log processing failures include, but are not limited to, failures in the application server log capturing mechanisms or log storage capacity being reached or exceeded. In some instances, it is preferred to send alarms to individuals rather than to an entire group. Application servers must be able to trigger an alarm and send an alert to, at a minimum, the SA and ISSO in the event there is an application server log processing failure.
STIG Date
Nutanix AOS 5.20.x Application Security Technical Implementation Guide 2022-08-24

Details

Check Text ( C-57590r846401_chk )
Confirm Nutanix AOS is set to send SMTP alerts to the organization identified email address(es).

1. Log in to Nutanix Prism Elements.
2. Select "Health" dashboard.
3. On the Actions tab, select "Set NCC Frequency".

If the Frequency setting and email address(es) are not set to organization-identified frequency and recipient, this is a finding.
Fix Text (F-57541r846402_fix)
Configure Nutanix Cluster Check (NCC) within Prism Elements to meet the Organization identified frequency and recipient.

1. Log in to Nutanix Prism Elements.
2. Select "Health" dashboard.
3. On the Actions tab, select "Set NCC Frequency".
4. Enter frequency timeframe.
5. Enter recipient email address(es).