UCF STIG Viewer Logo

The ICS must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes.


Overview

Finding ID Version Rule ID IA Controls Severity
V-258624 IVCS-NM-000720 SV-258624r930560_rule Medium
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
STIG Date
Ivanti Connect Secure NDM Security Technical Implementation Guide 2023-10-17

Details

Check Text ( C-62364r930558_chk )
In the ICS Web UI, navigate to Authentication >> Auth Servers >> Administrators.
1. Under the section "Account Lockout", verify "Enable Account Lockout for users" is checked.
2. Under the section "Account Lockout", verify "Maximum wrong password attempts" is set to "3".
3. Under the section "Account Lockout", verify "Account Lockout Period in Minutes" is set to "15".

If the ICS must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes, this is a finding.
Fix Text (F-62273r930559_fix)
In the ICS Web UI, navigate to Authentication >> Auth Servers >> Administrators.
1. Under the section "Account Lockout", check the box for "Enable Account Lockout for users".
2. Under the section "Account Lockout", set the box "Maximum wrong password attempts" to "3".
3. Under the section "Account Lockout", set the box "Account Lockout Period in Minutes" to "15".
4. Click "Save Changes".